Specifications
LASER
| Laser Source: | Q-switched Nd:YAG 1064nm |
| Energy Settings (single puls): | max. 10mJ (27 steps 0.2 - 10mJ) |
| Spot Size: | 7 µm |
| Cone Angle: | 16 degrees |
| Pulse Duration: | 4 ns |
| Pulse Setting: | 1, 2 or 3 pulses per burst |
| Repetition Frequency: | 3 Hz |
| Aiming Beam: | Dual rotating mode beam ( 633nm ), variable intensity and variable rotating speed enveloping the treatment laser beam. Defocus posterior / anterior. |
| Spot Size | 50 µ (approx.) |
| Electrical Requirements: | 100 - 240 V VAC, 45 - 65 Hz, 700 VA |
| Minimum/Maximum Height: | 70 cm / 90 cm (table) |
| Table Dimensions: | 90 cm (L) x 62 cm (W) |
| Application Range: | Posterior Capsulotomy Peripheral Iridotomy Pupillary Membranectomy |
LASER SLIT LAMP
| Type: | Original Haag Streit 900 BQ® |
| Slit image width: | 0 - 8 mm continuous |
| Slit image length: | 1 - 8 mm continuous |
| Illumination field diameter: | 8, 5, 3, 2, 1, and 0.2 mm (Test mark with fixation star) |
| Slit image radial range: | ± 90° |
| Radial movement to the microscope axis: | Horizontal ± 40° |
| Filters: | blue, red-free (green), grey (10 %), heat absorption filter |
| Light Source: | Tungsten incandescent light bulb 6V / 4.5A |
| Illumination intensity: | 0 - 380 000 Lux |
STEREO-MICROSCOPE
| Objective lens focal length: | 105 mm |
| Magnification changer: | 6.3x 10x 16x 25x 40x (optional) |
| Ocular magnification: | 12.5x |
| Range of adjusting oculars: | +8 to -8 diopters |
| Inter-pupillary distance: | 52 - 78 mm |
The specifications are subject to change without notice.
|
|
|
Optional accessories Haag-Streit BQ 900 compatible:
Beam splitter Haag-Streit, Co-oberservation tube Haag-Streit, Digital photo and video adapter Haag-Streit, various Laser contact lenses Haag-Streit, 5x Magnification changer Haag-Streit and Tonometer Haag-Streit.
Microruptor V - the smart choice
Ergonomic design for full patient- and doctor access. Fully wheelchair accessible motorised table. Left and right hand operation controls on column. Easy to read menu on control panel. Posterior and anterior defocusing of the position of the treatment focal plane at optimal 0.4mm. Optimal setting for Iridotomy (repetition rate matches the "Eigenfrequency"). Easy to use double and triple bursts for Iridotomy. Integrated HAAG-STREIT BQ slit lamp, the finest Swiss optics for optimal view and examination. Compatible with most HAAG-STREIT BQ 900 accessories. Unique rotation aiming beam for precise and safe focusing. Easy to upgrade to a combination system with MERILAS 532 alpha green laser photocoagulator.
MERIDIAN has been designing, manufacturing, and maintaining ophthalmic lasers for more than twenty five years. Since the introduction of the first Nd:YAG laser by Prof. Fankhauser, University of Berne Eye Clinic in 1982, Thun has become the place where superior ophthalmic lasers are designed and built.
A worldwide distributor network ensures comprehensive service support throughout the world.
Specifications are subject to change without previous notice